As with any window installation method, the rough opening must be prepared by ensuring flush, level, smooth clean, dry surface. The sheathing must be trimmed properly to support the window frame and ensure long-term structural integrity of the exterior construction wall.

Apply PM-7000 liquid applied flashing membrane (#1 in diagram) to bottom of opening and out nine inches to side of opening at lower portion of opening. Do not apply material to sheathing below rough opening.

PM-7000 is packaged in cartridges or bulk to be applied with standard caulk tools then brushed, rolled or troweled to desired coating thickness.

While PM-7000 is still wet, install pre-creased fabric counter-flashing (#3 in diagram) three inches above bottom of opening extending nine inches to both sides. Cut textile flashing at sides of opening to the bottom of opening and told over still. Press Fabric counter-flashing into liquid with broad knife.

Apply PM-7000 to the balance of the rough opening (Areas 1,2 and 8 of diagram), over fabric counter-flashing at still and out nine inches at sides and top of opening. PM-7000 will not be transparent when applied at the correct thickness of 12 mils.
After PM-7000 has dried to touch (15-30 minutes) the opening is ready fro windows installation but can be exposed to weather for extended periods without damage.

Install window, with drainage mesh or shims at bottom flange to allow for water management.

Push closed-cell foam backer rod (#5 in diagram) into gap around interior side of window frame to ensure a proper depth to width ratio.

Apply WS-7100 interior seal (#4 in diagram) around entire frame at interior side of window. Tool uncured sealant with appropriate equipment (spatula) to ensure proper contact with window frame and coated rough opening surfaces.

To view application sequence and larger images, please click on photos.

  Step by Step Application Process

1. ) Tools Needed
2. ) Apply PM-7000 to Sill Area.
3. ) Apply PM-7000 to Sill Area.
4. ) Apply PM-7000 to Sill Area.
5. ) Apply Transition Material at Sill.
6. ) Apply Transition Material at Sill.
7. ) Apply PM7000 to Rough Opening.
8. ) Apply PM-7000 to Rough Opening.
9. ) Install Window.
10. ) Install Backer Rod
11. ) Apply WS-7100 interior seal (#4 in diagram) around entire frame at interior side of window.
12. ) Tool uncured sealant.
» Contact BEI

» About BEI

» Home



Liquid Applied Flashing System Information Sheet

Wet-Flash® PM-7000 Data Sheet
Wet-Flash® PM-7000 MSDS

Wet-Flash® WS-7100 Data Sheet
Wet-Flash® WS-7100 MSDS

Installation/Application Guide

BEI 07650 Flexible Flashing Spec

BEI Wet-Flash 07920 Caulking Sealant Spec

Can't read PDFs? Click here to download Adobe Acrobat Reader.




Home | Wet-Flash® PM-7000 | Wet-Flash® WS-7100 | Installation/Application Guide | Test Chamber | About BEI | Contact BEI | Distributor List
©2006 BEI, Inc. All rights reserved. Design by Site Specific.